Red Seal Gasfitter Class A Exam Guide (2026): 100 Questions & Weighting
The Red Seal Gasfitter – Class A exam covers the same seven Major Work Activities as Class B, but the work behind it is larger: the Red Seal Occupational Standard describes Class A gasfitters working on appliances and equipment exceeding 400 000 Btuh (120 kW), in commercial, institutional and industrial plants. The standard also states plainly that as the volume of fuel gas at a facility increases, so does the risk. Expect questions about gas trains, flame safeguards, combustion tuning and plant start-up, not only about house furnaces.
🔥 Gasfitter Class A Exam Quick Blueprint
- Total Exam Questions: 100 multiple-choice questions
- Time Allowed: 4 hours (240 minutes)
- Passing Mark: 70% (70 out of 100 correct)
- Main Codes: CSA B149.1 (natural gas and propane installation) and CSA B149.2 (propane storage and handling), in the edition your province adopts
1. Official Major Work Activity (MWA) Weighting Breakdown
The weighting is very different from Class B. Testing and commissioning (MWA F) carries 23 questions, the largest block, and controls and electrical systems (MWA D) carries 19. Together with servicing (MWA G, 18 questions), those three blocks are 60 of the 100 questions.
| Major Work Activity (MWA) | Weighting | Exam Questions |
|---|---|---|
| MWA A: Performs Common Occupational Skills | 5.0% | 5 |
| MWA B: Installs Fuel Piping and Tubing Systems | 9.0% | 9 |
| MWA C: Installs Venting and Air Supply Systems | 13.0% | 13 |
| MWA D: Installs Controls and Electrical Systems | 19.0% | 19 |
| MWA E: Installs and Converts Fuel Systems, Appliances and Ancillary Equipment | 13.0% | 13 |
| MWA F: Tests and Commissions Fuel Systems, Appliances and Ancillary Equipment | 23.0% | 23 |
| MWA G: Services Fuel Systems, Appliances and Ancillary Equipment | 18.0% | 18 |
Source: red-seal.ca exam breakdown for Gasfitter – Class A.
2. Where Class A Questions Go Deeper
- Controls (MWA D): combustion control, flame safeguard and operating control systems, electrical systems, and automation and instrumentation controls. Read sequences step by step: purge, trial for ignition, flame proving, then the run.
- Testing and commissioning (MWA F): testing fuel delivery systems and commissioning appliances and ancillary equipment. Pressure tests, purging, start-up checks and combustion readings are the core of the largest block.
- Venting and air supply (MWA C): venting systems, air supply and draft control systems on larger equipment.
- Fuel systems (MWA E): appliances and conversions, propane and natural gas storage, handling and dispensing, and other fuel storage systems.
3. Formulas From the Official Formula Sheet
- Gas flow from input:
CFH = input (Btuh) ÷ heating value(natural gas about 1 000 BTU/ft³, propane about 2 500 BTU/ft³). - Meter clocking:
CFH = 3 600 × dial size ÷ seconds per rotation, with a pressure factor for meters set above base pressure. - Boiler output:
Btuh = BHP × 33 500 × number of boilers. - Purge time:
time = CFM × number of air changes ÷ SCFM.
4. A Study Plan That Matches the Weighting
Spend the most time where the questions are: commissioning, controls and service. Work through each block with timed practice at about 2.4 minutes per question (240 minutes ÷ 100 questions), log every miss, and return to the missed tasks before the next full mock exam.
Ready to Test Your Gasfitter Class A Readiness?
Try free sample questions or launch a timed 100-question mock exam mapped to the official blueprint.
Free Practice Questions 100-Question Mock ExamTake the Gasfitter – Class A Exam Simulation
Access full-length timed exam simulations, Red Seal question banks checked twice, comprehensive Canadian code references, and instant AI Journeyperson explanations.