Red Seal Pass
← Back to the blog
Red Seal Study Blog

Red Seal Plumber Practice Exam: National Plumbing Code (NPC) Questions & Solutions

Passing the Interprovincial Red Seal Plumber Examination

The Red Seal Plumber exam tests a tradesperson's ability to interpret blueprints, size drainage and venting systems under the National Plumbing Code of Canada (NPC), and troubleshoot hydronic heating and potable water supply systems.

Exam Structure and Task Distribution

Sample Practice Question & Solution

Question 1: Under the National Plumbing Code (NPC), what is the maximum developed length of a 1-1/2 inch trap arm servicing a lavatory before a vent pipe is required?

A) 1.2 meters (4 ft)
B) 1.5 meters (5 ft)
C) 1.8 meters (6 ft)
D) 2.4 meters (8 ft)


Correct Answer: B) 1.5 meters (5 ft)

Explanation: According to NPC Table 2.4.9.2, for a 1-1/2 inch pipe size with a minimum grade of 1:50 (1/4 in per foot), the maximum fixture drain length (trap arm) is 1.5 m (5 ft).

Master Your Plumbing Math

Be prepared for 45-degree offset calculations (1.414 × travel) and rolling offset geometry. Bringing a reliable non-programmable calculator and knowing how to quickly compute fixture unit loads (FU) will save critical time during the exam.

Take Red Seal Plumber Practice Test →

Study along with me

Free Red Seal practice questions with full explanations, plus spaced-repetition review that actually sticks.

Free Practice Questions See Plans