Certifying authority: Skilled Trades Ontario (STO). Last checked 2026-09-10.
This trade is on Ontario’s compulsory list as Steamfitter (307A). Under Skilled Trades Ontario, workers must hold a valid Certificate of Qualification, a Provisional Certificate of Qualification, or a Registered Training Agreement; journeypersons must renew their C of Q each year. Official list PDF is dated Feb 2022; the count of 23 still matches the current STO page.
Source: Skilled Trades Ontario — Compulsory Trades (23 trades)
Start with 10 free interactive Steamfitter / Pipefitter (307A) questions with worked explanations, or take a full 130-question timed mock exam weighted to the official RSOS breakdown.
Try the 10-Question Interactive Steamfitter / Pipefitter (307A) Quiz & Free PDF → Take Full 130-Question Timed Mock Exam ($14.99 CAD) →Or unlock all Steamfitter / Pipefitter (307A) questions with the 7-Day Pass ($9.99) or 3-Month Pass ($69.99, Free-Until-You-Pass Guarantee).
Whether it is required or not, the exam itself is the same paper everywhere in Canada. What your province decides is whether you must hold the certificate, how you apply, and where you sit it.
The Red Seal Occupational Standard sets the split below. It does not change by province.
| Major Work Activity | Weighting | Questions |
|---|---|---|
| MWA A: Performs common occupational skills | 12% | 16 Qs |
| MWA B: Performs layout, fabrication and piping installation | 22% | 29 Qs |
| MWA C: Performs rigging, hoisting, lifting and positioning | 12% | 15 Qs |
| MWA D: Installs, tests, maintains, troubleshoots and repairs low and high pressure steam and condensate systems | 18% | 24 Qs |
| MWA E: Installs, tests, maintains, troubleshoots and repairs heating, cooling and process piping systems | 21% | 27 Qs |
| MWA F: Installs, tests, maintains, troubleshoots and repairs renewable energy systems | 6% | 8 Qs |
| MWA G: Performs commissioning, start-up and turnover | 8% | 11 Qs |
Source: Red Seal Exam Breakdown — Steamfitter / Pipefitter (307A), red-seal.ca
4 hours, and a 70% pass mark (91/130). These are set provincially rather than by the Red Seal standard, and the four hours is the same whether your paper is 100 or 150 questions.
Confirmed against Skilled Trades Ontario’s Exam Preparation Guide and SkilledTradesBC. Check your own authority before exam day.
Click any option (A–D) below to grade yourself immediately and view the worked explanation:
The meter is zeroed in clean air, not inside the tank. Oxygen is read first because many flammable-gas sensors need enough oxygen to read correctly; flammable gas and then toxic gases follow, each judged against the permit limits. The other options use the same steps in the wrong order: B does 'read the flammable gas (LEL)' before 'read the oxygen level', C does 'read the toxic gases (H2S, CO)' before 'read the oxygen level', and D does 'read the toxic gases (H2S, CO)' before 'zero the meter in fresh air outside'.
Regular inspection requirements are documented, and knots and hitches are inspected and retied. An old knot may have weakened the rope, and more tension does not repair it.
Relief valves set below the test pressure are removed, blanked or gagged, and a temporary test relief is used. Temporary supports carry the water weight, vents clear the air while filling, and the pressure is raised on calibrated gauges. The other options use the same steps in the wrong order: A does 'raise pressure on calibrated gauges' before 'remove or blank the relief valves', B does 'fill it with the vents open' before 'fit temporary supports for the water', and D does 'raise pressure on calibrated gauges' before 'fill it with the vents open'.
Booking is handled by Skilled Trades Ontario (STO); confirm current locations and dates with them.
Our Steamfitter / Pipefitter (307A) question bank is built to the official RSOS weighting above, with a worked explanation and code citation on every question.
Continue to Full 10-Question Interactive Steamfitter / Pipefitter (307A) Quiz → Take the full 130-question timed mock exam →