Red Seal Pass
Red Seal Pass › Gasfitter – Class B › British Columbia (BC)

Gasfitter – Class B Red Seal Exam in British Columbia (BC)

Certifying authority: SkilledTradesBC (formerly ITA BC). Last checked 2026-11-20.

Certification is required in British Columbia (BC)

This trade is on British Columbia (BC)’s compulsory list as Gasfitter Class A and Class B. Under SkilledTradesBC, workers must be a registered apprentice, a registered trade qualifier, or a certified journeyperson.

Source: SkilledTradesBC — Skilled Trades Certification (compulsory trades)

Preparing for the Gasfitter – Class B exam in British Columbia (BC)?

Start with 10 free interactive Gasfitter – Class B questions with worked explanations, or take a full 100-question timed mock exam weighted to the official RSOS breakdown.

Try the 10-Question Interactive Gasfitter – Class B Quiz & Free PDF → Take Full 100-Question Timed Mock Exam ($19.99 CAD) →

Or unlock all Gasfitter – Class B questions with the Monthly Pass ($39.99/mo) or 6-Month Pass ($89.99, 7-Day Money-Back & Pass Guarantee).

Whether it is required or not, the exam itself is the same paper everywhere in Canada. What your province decides is whether you must hold the certificate, how you apply, and where you sit it.

The exam: 100 questions, 7 Major Work Activities

The Red Seal Occupational Standard sets the split below. It does not change by province.

Major Work ActivityWeightingQuestions
MWA A: Performs common occupational skills 7% 7 Qs
MWA B: Installs fuel piping and tubing systems 14% 14 Qs
MWA C: Installs venting and air supply systems 15% 15 Qs
MWA D: Installs controls and electrical systems 15% 15 Qs
MWA E: Installs and converts fuel systems, appliances and ancillary equipment 15% 15 Qs
MWA F: Tests and commissions fuel systems, appliances and ancillary equipment 16% 16 Qs
MWA G: Services fuel systems, appliances and ancillary equipment 18% 18 Qs

Source: Red Seal Exam Breakdown — Gasfitter – Class B, red-seal.ca

Time allowed and pass mark

4 hours, and a 70% pass mark (70/100). These are set provincially rather than by the Red Seal standard, and the four hours is the same whether your paper is 100 or 150 questions.

Confirmed against Skilled Trades Ontario’s Exam Preparation Guide and SkilledTradesBC. Check your own authority before exam day.

Quick 3-Question Gasfitter – Class B Readiness Check

Click any option (A–D) below to grade yourself immediately and view the worked explanation:

Sample Question 1 of 3
You are replacing an old cast-iron boiler in the basement of a 1950s apartment block in Winnipeg. While checking how the new vent connector will meet the breeching, you pull back a corner of the grey, chalky wrap on the breeching and it crumbles in your hand. The owner does not know what the wrap is made of, and the demolition of the old breeching is booked for this afternoon. What should you do first?
A) Wet the wrap down, put on a dust mask and strip it off carefully in large pieces
B) Stop, keep others out of the area and report it so the wrap is sampled and tested
C) Cover the torn corner with duct tape and carry on with the demolition as booked
D) Vacuum the loose wrap with the shop vacuum, bag it and then start the demolition
Correct answer: B

A crumbling, unidentified wrap on old breeching may contain asbestos, so the work stops, the area is kept clear and the hazard is reported to the owner and supervisor so a qualified person can sample it before anything else is disturbed. Option A treats the wrap as a do-it-yourself removal with a dust mask, which is not respiratory protection for asbestos and is not a removal procedure. Option C hides the damage and still lets the demolition disturb the material. Option D uses an ordinary shop vacuum, which blows fine fibres back into the room. A and D both remove the wrap before anyone knows what it is.

Sample Question 2 of 3
A natural-draft water heater in a Quebec City duplex spills at the draft hood only on windy days from the west. Its vent ends with a listed cap at the height the code requires, but a new four-storey building now stands a few metres to the west, rising well above the cap. The vent is clear and sized correctly. What should you conclude?
A) The cap is too high, so cut the vent down below the roof line of the house
B) The heater is overfired on windy days, so lower its manifold pressure
C) The vent is too large in windy weather, so reduce it by one diameter
D) Wind over the taller building pushes down onto the cap, so extend or move it
Correct answer: D

Wind passing over a taller building sets up downwash and swirling eddies on its downwind side, and a low cap in that wake has air pushed down onto it, so the vent is extended or moved, as the vent maker allows, to get clear of it. Option A lowers the cap further into the disturbed air. Option B changes the burner, which has nothing to do with wind. Option C shrinks a vent that is sized correctly. A and C both change the vent in a way that makes it worse.

Sample Question 3 of 3
You arrive at a Kelowna townhouse site to test the gas piping with nitrogen at the 15 psig set by the inspector. The cylinder is lying loose in the truck bed with its valve cap off, and the regulator in the van has a cracked gauge lens and no relief valve on its outlet. A spare regulator in good condition and a relief valve are in the shop ten minutes away. What should you do before connecting to the piping?
A) Stand the cylinder up and chain it, keep the cap on until use, and fit a sound regulator with a relief valve on the rig
B) Leave the cylinder lying in the truck bed, fit the cracked regulator, and crack the valve slowly while watching the gauge
C) Stand the cylinder up and chain it, fit the cracked regulator, and rely on the test gauge on the piping to show pressure
D) Leave the cylinder lying in the truck bed, fit a sound regulator with a relief valve, and open the valve fully once fitted
Correct answer: A

A compressed gas cylinder is stood up and secured with its cap on until use, and a sound regulator with a relief valve keeps the piping from seeing full cylinder pressure if anything fails. Option B leaves the cylinder loose and trusts a damaged regulator with no relief, so a failure puts cylinder pressure into the piping. Option C secures the cylinder but still uses the damaged regulator, and the test gauge only shows overpressure after it happens. Option D fits the right regulator but leaves the cylinder loose, where a broken valve can turn it into a projectile. A and C differ only in the regulator used.

Where you write it in British Columbia (BC)

Booking is handled by SkilledTradesBC (formerly ITA BC); confirm current locations and dates with them.

Preparing for the Gasfitter – Class B exam

Our Gasfitter – Class B question bank is built to the official RSOS weighting above, with a worked explanation and code citation on every question.

Continue to Full 10-Question Interactive Gasfitter – Class B Quiz → Take the full 100-question timed mock exam →

Other provinces